Skip to Content

Sikagard 140 Pool, Pool Paint, 10L

Cement & Mortar
SIKA

Sika is a global leader in specialty chemicals for the construction and industrial sectors. The company develops and supplies innovative products and systems for bonding, sealing, damping, reinforcing, and protecting structures. With a strong focus on sustainability and performance, Sika serves a wide range of applications including concrete production, waterproofing, roofing, flooring, and structural strengthening.

Read more
https://www.polytrade.global/web/image/product.template/40658/image_1920?unique=f2e1e15

3,881.68 lei Tax Included
3881.68 RON

Not Available For Sale

You have already submitted a query for this product today.

This combination does not exist.

Acrylic, specialist, water-based coating for swimming pool lining

Sikagard®-140 Pool is a one-part, water-based, coloured, specialist acrylic resin coating with good resistance to chlorine treated water.

Usage

Sikagard®-140 Pool is used as a:

  • Protective coating for interior and exterior concrete pools.
  • Protective coating for interior and exterior chlorinated swimming pools using automatically controlled water treatment equipment.

Sikagard®-140 Pool is used on the following substrates:

  • Concrete.
  • Sikagard®-720 EpoCem®.
  • Sikafloor®-81 EpoCem®.
  • Water resistant fibre cement panels (NOT permanently immersed in water).
  • Chlorinated rubber coatings.
  • Sikagard®-140 Pool.
Advantages
  • One-part, ready to use.
  • Can be applied onto various substrates.
  • Easy to apply and to refurbish, can be overcoated directly with itself.
  • Good yellowing resistance.
  • Good chalking resistance.
  • Good resistance to fatty acids from lotions and cosmetics.
  • Good resistance to chlorinated water and common swimming pool cleaning chemicals.
  • Good opacity (covering power).
  • With the addition of kiln-dried quartz sand, slip-resistance can be achieved.
Packaging
One-Part Container10 Litres

Refer to the current Price List for available packaging variations.

Colour
Cured colourAvailable in 4 colours: White, Black, Adriatic Blue and Lake Green.
Typical Product Data
APPROVALS / STANDARDS

- CE marking and declaration of performance based on EN 1504-2:2004 Products and systems for the protection and repair of concrete structures — Surface protection systems for concrete — Coating

Chemical Base

Water-based, specialist acrylic resin

Shelf Life

12 months from date of production

Storage Conditions

The Product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C (+41 °F) and +25 °C (+77 °F). Always refer to the packaging.
Refer to the current Safety Data Sheet for information on safe handling and storage.

Density

1.34 kg/l (11.2 lb/gal) (EN ISO 2811-1)

Solid content by mass

63.5 %

Solid content by volume

50.9 %

Chemical Resistance

Resistant to acidic and alkaline detergents, disinfectants and chlorinated water in swimming pools with controlled water treatment equipment.
NOT resistant to organic solvents.
At a higher chlorine concentration (> 0.6 mg/l) or water treatment by ozone (DIN 19643-2) chalking of the surface and discoloration might occur. A refurbishment layer of Sikagard®-140 Pool might become necessary for aesthetic reasons. Sikagard®-140 Pool is NOT suitable for pools using disinfection treatment based on electrolysis.

Skid / Slip Resistance

To achieve a slip / skid resistant texture, add ~5 % by weight kiln-dried 0.1-0.3mm (0.0039-0.0118 in) quartz sand. Whilst stirring, add the appropriate amount of sand (for each 10 litre unit, 670 g (23.6 oz) of sand is sufficient) to the unit and continue mixing for at least 1 minute until evenly dispersed.

Application
Layer Thickness

~120 µm wet film thickness per layer

Product Temperature
Maximum+30 °C (+86 °F)
Minimum+8 °C (+46 °F)
Ambient Air Temperature
Maximum+30 °C (+86 °F)
Minimum+8 °C (+46 °F)
Relative Air Humidity
Maximum80 % r.h.
Dew Point

Beware of condensation. The substrate and uncured applied Product must be at least +3 °C (+37 °F) above the dew point to reduce the risk of condensation or blooming on the surface of the applied Product. Low temperatures and high humidity conditions increase the probability of blooming.

Substrate Temperature
Maximum+30 °C (+86 °F)
Minimum+8 °C (+46 °F)
Substrate Moisture Content
SubstrateTest Method Moisture Content
Cementitious substratesCalcium carbide method (CM-method) ≤ 6 %

No rising moisture (ASTM D4263, polyethylene sheet).

Waiting Time / Overcoating
TemperatureMinimum Maximum
+20 °C (+68 °F)~16 hours ~3 days
+10 °C (+50 °F)~40 hours ~4 days

NOTE: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.

Applied Product Ready for Use

Before filling the pool leave Sikagard®-140 Pool to cure for at least 14 days after the final application. The temperature must NOT be below +10 °C (+50 °F) during the curing process.

NOTE: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.

Consumption

160 g/m² per layer, minimum 2 layers to be applied.

NOTE: Consumption data is theoretical and does not allow for any additional material due to surface porosity, surface profile, variations in level, wastage or any other variations. Apply the Product to a test area to calculate the exact consumption for the specific substrate conditions and proposed application equipment.

APPLICATION INSTRUCTIONS

IMPORTANT

Strictly Follow Installation Procedures

Strictly follow installation procedures as defined in Method Statements, Application Manuals and Working Instructions, which must always be adjusted to the actual site conditions.

EQUIPMENT

APPLICATION EQUIPMENT

  • Brush
  • Fleece roller
  • Airless spray equipment

For airless spray application use the following settings:

Pressure:180 bar
Nozzle bore:0.38 – 0.66 mm (0.015 – 0.026 in)
Spray angle:40 – 60 °
SUBSTRATE QUALITY

Existing coatings must be tested to confirm their adhesion to the substrate and their compatibility. As guidance, adhesion test average ≥ 0.8 N/mm 2 (116 psi) with no single value below 0.5 N/mm 2 (72.5 psi) .

SUBSTRATE PREPARATION

IMPORTANT

Surface defects due to voids in the substrate

Voids and blow holes in the substrate will weaken the surface and damage the covering Product if not repaired during the preparation process.

  1. Fully expose blow holes and voids during surface preparation to identify the required repairs.

EXPOSED CONCRETE OR CEMENTITIOUS RENDER

  1. Remove weak cementitious substrates.
  2. Prepare cementitious substrates mechanically using abrasive blast cleaning, abrasive planing or scarifying equipment to remove cement laitance.
  3. Before applying thin layer resins, remove high spots by grinding.
  4. Before applying the Product, remove all dust, loose and friable material from the application surface with an industrial vacuuming equipment.
  5. Use Sikagard®-720 EpoCem® or Sikafloor®-81 EpoCem® to level the surface or fill cracks, blow holes and voids.

For additional information on Products for levelling and repairing defects, contact Sika® Technical Services.

COATED SUBSTRATE WITH INADEQUATE ADHESION

  1. Remove existing coatings using suitable removal equipment such as abrasive blast cleaning or high pressure water jetting.
  2. Prepare cementitious substrates mechanically using abrasive blast cleaning, abrasive planing or scarifying equipment to remove cement laitance.
  3. Before applying thin layer resins, remove high spots by grinding.
  4. Before applying the Product, remove all dust, loose and friable material from the application surface with an industrial vacuuming equipment.
  5. Use Sikagard®-720 EpoCem® or Sikafloor®-81 EpoCem® to level the surface or fill cracks, blow holes and voids.

COATED SUBSTRATE WITH ADEQUATE ADHESION

  1. Thoroughly clean the surface of all contaminants using pressured water cleaning equipment.
  2. Lightly abrade or grind the surface with mechanical grinding or abrading equipment to achieve a sheen free surface.
  3. Before applying the Product, remove all dust, loose and friable material from the application surface with an industrial vacuuming equipment.
APPLICATION

IMPORTANT

Ventilation in confined spaces

Always ensure good ventilation when applying the Product in a confined space.

Exposure to direct sunlight

NOTE: When the product is exposed to direct sunlight, there may be some discolouration and colour variation. This has no influence on the function and performance of the coating.

SPRAY APPLICATION

  1. Spray apply the Product in a continuous operation and at a speed to achieve a consistent thickness and surface finish.
  2. Control the layer thickness during application using a thickness gauge.
  3. The coating must be continuous, pore free and to the required surface finish.
  4. Protect Product from rain, condensation and water for at least 24 hours at +20 °C (+68 °F) and at least 48 hours at +10 °C (+50 °F).
  5. Apply additional coats as required.

MANUAL APPLICATION

  1. Apply the Product evenly over the surface with a short pile fleece roller at the required consumption.
  2. Control the layer thickness during application using a thickness gauge.
  3. To achieve a smooth finish, smooth the surface with a brush.
  4. The coating must be continuous, pore-free and to the required surface finish.
  5. Protect Product from rain, condensation and water for at least 24 hours at +20 °C (+68 °F) and at least 48 hours at +10 °C (+50 °F).
  6. Apply additional coats as required.
CLEANING OF TOOLS

Clean all tools and application equipment with water immediately after use. Hardened / cured material can only be removed mechanically.