Cementitious General Purpose Grout
SikaGrout® 111 GP is a one part flowable shrinkage compensated general purpose cementitious grout. Meets the requirements of EN 1504-6: Anchoring of reinforcing bars.
-
Easy to use (ready to mix powder).
-
Pre-batched for quality.
-
Just add water.
-
High compressive strength gain.
-
Easy to mix and apply.
-
Contains no chloride admixtures.
-
Shrinkage compensated.
-
Fire rating and protection properties comparable to concrete.
-
Can be pumped or poured.
-
Good mechanical properties.
|
Usage
- General purpose grouting.
- Under stanchion plates.
- Filling cavities, voids, gaps and recesses.
- Sealing around penetrations.
- Machine and base plates.
- Post fixings.
- For exterior and interior use.
Advantages
- Easy to use (ready to mix powder).
- Pre-batched for quality.
- Just add water.
- High compressive strength gain.
- Easy to mix and apply.
- Contains no chloride admixtures.
- Shrinkage compensated.
- Fire rating and protection properties comparable to concrete.
- Can be pumped or poured.
- Good mechanical properties.
|
Technical Information
Compressive Strength
1 day | 7 days | 28 days | Test | ~20MPa | ~40MPa | ~45MPa | EN 12190 |
Modulus of Elasticity in Compression
Tensile adhesion strength
~2.5MPa (28 days) | (EN 1542) |
Shrinkage
~0.07% (<1mm/M)
Reaction to Fire
Euroclass A1 | (EN 13501-1) |
|
Application Information
Mixing Ratio
Water : mortar powder = 1 : 6.25 parts by weight. (4.0 – 4.5 litres of water per bag)
Layer Thickness
10mm minimum / 150mm maximum
Flowability
~695mm (0 mins) ~480mm (30mins) | (EN 13395-2)) |
Ambient Air Temperature
+5°C minimum / +30°C maximum
Substrate Temperature
+5°C minimum / +30°C maximum
Setting time
Initial ~210 minutes Final ~300 minutes | (EN 13294) |
|
The above design is only a sample of the options available, for reference purposes only. Our policy of continuous improvement may result in a change of specifications without notice. If any discrepencies might be between the data sheet values and standards, we reserve the rights to make technical changes. Our company will not be held responsible, as all or any of pictures, drawings, weights and dimensions details or other elements in this document are only indicative and must not be considered contractual. Contact our sales team for other specifications or custom made products.
Contact our sales team for other specifications or custom made products.