High performance non-sagging structural adhesive SikaForce-818 L07 is a structural 2-component polyurethane adhesive, which cures at room temperature.It is designed for bonding composite components. The adhesive is characterised by fast curing and strength build-up. While uncured, it has very good non-sag and compressibility behaviour. - Very good non-sag behaviour
- Short curing time
- High strength and modulus for structural bonding applications
- Low smell
- Does not contain solvents or PVC
|
PRODUCT BENEFITS - Very good non-sag behaviour
- Short curing time
- High strength and modulus for structural bonding applications
- Low smell
- Does not contain solvents or PVC
Usage SikaForce-818 L07 is used for various bonding applications in the wind turbine manufacturing process, e.g. the attachment of mounting parts, lightning protection etc. This product is suitable for experienced professional users only. Tests with actual substrates and conditions have to be performed ensuring adhesion and material compatibility. Packaging SikaForce-818 L07 (A) Can | 1 kg | Pail | 20 kg | Drum | 240 kg |
SikaForce-050 (B) Can | 0.45 kg 1 kg 5 kg | Pail | 25 kg | Drum | 250 kg |
SikaForce-818 L07 (A+B) Coaxial cartridge | 195 ml | |
Mixer: MCH 10-24T by Medmix |
Dual cartridge | 400 ml | |
Mixer: MFH 10-24T by Medmix | |
Typical Product DataCure mechanism | | Polyaddition | Mixing ratio | by volume | 100 : 45 | Application temperature | | 10 ─ 35 °C | Pot life (CQP536-2) | | 7 minutes A | Open time (CQP046-11 / ISO 4587) | | 3 minutes A | Shore D hardness (CQP023-1 / ISO 48-4) | | 75 A, B | Tensile strength (CQP036-2 / ISO 527) | | 30 MPa A, B, C | Elongation at break (CQP036-2 / ISO 527) | | 3 % A, B, C | E-Modulus (CQP036-2 / ISO 527) | | 2 500 MPa A, B, C | Tensile lap-shear strength (CQP046-9 / ISO 4587) | | 20 MPa A, B, D | Glass transition temperature (CQP509-1 / ISO 6721) | | 55 °C B |
Component ASikaForce-818 L07 | Component BSikaForce-050 |
|
Technical Information CURE MECHANISM The curing of SikaForce-818 L07 takes place by a chemical reaction of the two components. Higher temperatures speed up and lower temperatures slow down the curing process. The final glass transition temperature, as well as the tensile and shear strengths, may be increased with higher curing temperature. CHEMICAL RESISTANCE In case of chemical or thermal exposure, it is required to conduct project related testing. |
Application Information Surface Preparation Surfaces must be clean, dry and free from grease, oil, dust and contaminants. After the cleaning process, a physical or chemical pre-treatment might be required, depending on surface and type of material. The type of pre-treatment must be determined by tests. Application For the cartridge application use a suitable manual or a compressed air piston-type cartridge dispenser. To ensure good mixing quality the defined static mixer is to be used. Extrude adhesive without mixer to equalise the filling levels. Attach the mixer and dispose the first few cm of the bead before the application. SikaForce-818 L07 can also be processed from pails with adequate 2-component equipment. For automated applications, contact the System Engineering Department of Sika Industry. Removal Uncured SikaForce-818 L07 may be removed from tools and equipment with Sika Remover-208. Once cured, the material can only be removed mechanically. Hands and exposed skin have to be washed immediately using hand wipes such as Sika Cleaner-350H or a suitable industrial hand cleaner and water. Do not use solvents on skin. STORAGE CONDITIONS SikaForce-818 L07 has to be kept between 10 °C and 30 °C in a dry place. Do not expose it to direct sunlight or frost. After opening of the packaging, the content has to be protected against humidity. The lowest allowed temperature during transportation is -20 °C for max. 7 days. |
The above design is only a sample of the options available, for reference purposes only. Our policy of continuous improvement may result in a change of specifications without notice. If any discrepencies might be between the data sheet values and standards, we reserve the rights to make technical changes. Our company will not be held responsible, as all or any of pictures, drawings, weights and dimensions details or other elements in this document are only indicative and must not be considered contractual. Contact our sales team for other specifications or custom made products.
Contact our sales team for other specifications or custom made products.