Low odor epoxy primer, leveling mortar and mortar screed Sikafloor®-150 is a multi-purpose, low-odor, low-viscosity, two-component epoxy resin that can be used as an epoxy primer, leveling mortar and screed. |
UseThe product is used as: - Primer for concrete support layers, cementitious screeds and epoxy mortars
- Primer for normally absorbent to highly absorbent support layers
- Primer for Sika® epoxy and polyurethane floor systems
Advantages- Reduced odor
- Low viscosity
- Good penetration
- Excellent adhesion
- Multiple fields of use
pack| Component A | containers of 1.85 kg (4.08 lb), 7.4 kg (16.3 lb) or 18.5 kg (40.8 lb) | | Component B | containers of 0.65 kg (1.43 lb), 2.6 kg (5.73 lb) or 6.5 kg (14.3 lb) | | Component A+B | 2.5 kg (5.51 lb), 10 kg (22 lb) or 25 kg (55.1 lb) sets, ready to mix | | Component A | 180 kg (397 lb) or 1000 kg (2205 lb) drums | | Component B | 190 kg (419 lb) or 950 kg (2094 lb) drums | | Component A+B | 3 barrels of 180 kg (397 lb) + 1 barrel of 190 kg (419 lb) = 730 kg (1609 lb) / set |
See the current price list for available packaging options. Color| Component A | Clear liquid | | Component B | Brown liquid |
Exposure to direct sunlight Note: When the product is exposed to direct sunlight, some discoloration and color variations may occur. They have no impact on the function and performance of the layer. |
Typical technical data| SUSTAINABILITY | | - In accordance with LEED® v4 EQc 2: Low Emission Materials - In accordance with LEED® v4 MRc 2 (Option 1): Declaration and Optimization of Building Products–Product Environmental Declarations - In accordance with LEED® v4 MRc 4 (Option 2): Declaration and Optimization of Building Products - Material Composition | | APPROVALS / CERTIFICATIONS | | - CE Marking and Declaration of Performance in accordance with EN 1504-2:2004 Products and systems for the protection and repair of concrete structures — Protection against infiltration — Coating - CE Marking and Declaration of Performance in accordance with EN 13813:2002 Screed and screed materials — Screed materials — Characteristics and requirements — Synthetic resin based screed materials - Adhesion behavior test according to DIN EN 13578, Sikafloor®-150 + Sikafloor®-264 N, Test report No. P 12091-1 E, Kiwa - Test to determine the crack accommodation capacity of a Sikafloor®-150 coating system in accordance with ETAG 022, Test Report No. P 12607-2a-E, Kiwa | | Chemical base | | Solvent-free epoxy resin | | Validity period | | 24 months from the date of production | | Storage conditions | | The product must be properly stored in the original packaging, sealed and undamaged, in dry conditions, at temperatures between +5°C (+41 °F) and +30°C (+86 °F). Always refer to the product packaging/label. See the current Product Safety Data Sheet for information on safe handling and storage. | | Density | | Component A ~1.12 kg/l (~9.35 lb/gal) Component B ~0.99 kg/l (~8.26 lb/gal) Mixed product ~1.08 kg (~2.38 lb) /l | | Solids content in percent by weight | | ~100% | | Solids content in percent by volume | | ~100% | | Hardness in Shore D degrees | | After 7 days at +23 °C (+73 °F) ~80 | | Tear resistance | | > 1.5 N/mm² (218 psi) (mass failure of concrete) (EN 1542) | | Thermal resistance | | IMPORTANT Mechanical and chemical demands at high temperatures Mechanical and chemical demands applied simultaneously with exposure to temperatures up to +60 °C (+140 °F) can cause damage to the product/floor. Do not expose the Product to chemical or mechanical stress, to high temperatures Maximum +60 °C (+140 °F) |
|
ApplicationMixture ratio| Component A : Component B | 74 : 26 (by weight) |
Product temperature| Maximal | +30 °C (+86 °F) | | Minimum | +10 °C (+50 °F) |
Ambient air temperature| Maximal | +30 °C (+86 °F) | | Minimum | +10 °C (+50 °F) |
The relative humidity of the air Support temperature| Maximal | +30 °C (+86 °F) | | Minimum | +10 °C (+50 °F) |
Moisture content in the substrate| substrate | Test method Moisture content | | Cement support | Calcium carbide method (CM method) ≤ 4 % |
No rising moisture (ASTM D4263, polyethylene sheet test) Lifetime of the mixture| +10 °C (+50 °F) | ~60 minutes | | +20 °C (+68 °F) | ~30 minutes | | +30 °C (+86 °F) | ~15 minutes |
Note: Times are approximate and are affected by changes in ambient conditions, especially temperature and relative humidity. Waiting Time / RecoatingThe waiting time before applying solvent-free products over Sikafloor®-150 is: | Substrate temperature | Minimum Maximum | | +10 °C (+50 °F) | ~17 hours ~4 days | | +20 °C (+68 °F) | ~9 hours ~2 days | | +30 °C (+86 °F) | ~7 hours ~1 day |
The waiting time before applying solvent products over Sikafloor®-150 is: | Substrate temperature | Minimum Maximum | | +10 °C (+50 °F) | ~36 hours ~6 days | | +20 °C (+68 °F) | ~24 hours ~4 days | | +30 °C (+86 °F) | ~12 hours ~2 days |
Note: Times are approximate and are affected by changes in ambient conditions, especially temperature and relative humidity. Consumption| System | Product Consumption | | Primer | 1–2 × Sikafloor®-150 1–2 × 0.3–0.5 kg/m² | | Leveling mortar | 1 part Sikafloor®-150 + 1 part quartz sand (0.1–0.3 mm (0.0039–0.0118 in)) + 0.015 parts Sika® Extender T 1.7 kg/m²/mm | | Connecting bridge | 1–2 × Sikafloor®-150 1–2 × 0.3–0.5 kg/m² | | Epoxy screed (layer thickness 15–20 mm (0.591–0.787 in)) / Repair mortar | 1 part Sikafloor®-150 + 10 parts quartz sand 2.2 kg/m²/mm |
The following sand mixtures are suitable for layer thicknesses of 15–20 mm (0.591–0.787 in): - 25 parts quartz sand 0.1–0.5 mm (0.0039–0.0197 in)
- 25 parts quartz sand 0.4–0.7 mm (0.0157–0.0276 in)
- 25 parts quartz sand 0.7–1.2 mm (0.0276–0.0472 in)
- 25 parts quartz sand 2–4 mm (0.0787–0.157 in)
The maximum grain size must not exceed 1/3 of the final thickness of the layer. Aggregates and the most optimal mixture will be chosen depending on the shape of the granules and the temperature at which the application is made. Other system configurations are provided in the product data sheets. It is recommended that preliminary tests be carried out on mortar mixes to assess the optimal distribution of aggregate grain size. Note: These values are theoretical and do not take into account additional consumption due to surface porosity, surface profile, unevenness or losses, etc. To accurately calculate substrate-specific consumption with the proposed application equipment, apply the product to a test surface. EQUIPMENTMIXING EQUIPMENT - Electric mixer with double paddles (> 700 W, 300 - 400 rpm)
APPLICATION EQUIPMENT - Short hair stencil roller
- Rubber scraper
SUPPORT QUALITYThe cement support layer (concrete/screed) must be solid and have sufficient compressive strength (minimum 25 N/mm 2 (3626 psi) ), with a minimum pull-out strength of 1.5 N/mm 2 (218 psi) . The support must be clean and free of contamination, such as: impurities, residues, oils, fats, coatings or previous surface treatments, friable materials, etc. PREPARATION OF THE SUPPORTMECHANICAL PREPARATION OF THE SUBSTRATE IMPORTANT Surface defects due to voids in the substrate Cavities and surface defects in the substrate will weaken the surface and damage the coating product if not repaired during the preparation process. - Fully expose cavities and surface defects during surface preparation to identify necessary repairs.
- Weak cementitious support layers must be removed.
- In order to remove milk from the cement, the concrete supports must be prepared by techniques and with appropriate mechanical equipment, such as sandblasting with metal alice, scarification or milling.
- When applying thin resin coatings, use mechanical sanding to remove burrs and bumps.
- Use industrial vacuum equipment to remove dust and friable material from the surface before applying the Product.
- Use products from the Sikafloor®, Sikadur® and Sikagard® range of materials for leveling the surface or filling cracks and holes/gaps.
- Contact Sika Technical Department for further information on leveling and defect repair products.
PREPARATION OF OTHER TYPES OF SUPPORT LAYERS Contact the Sika technical department for further information on the preparation of other types of support. TREATMENT OF JOINTS AND CRACKS Constructive joints and surface static cracks existing in the support layer require prior treatment by local filling with material and leveling. In this way, the surface is sealed against material loss before the floor finish is applied. Use Sikadur® or Sikafloor® resins. shuffleNote: To increase the viscosity of the Product, Sika® Extender T can be added to the mixture. PRIMER MIXING PROCEDURE - Mix Component A (resin) for 30 seconds.
- Add Component B (the hardener) over Component A.
- IMPORTANT: Do not over mix. Mix Components A + B continuously for 3 minutes until a uniform mixture is obtained.
- To make sure they are mixed evenly, pour the contents into another container and mix until a homogeneous mixture is obtained.
- In the final mixing phase, scrape the sides and bottom of the container with a straight/flat-edged spatula or trowel at least once to ensure thorough mixing.
LEVELING MORTAR / EPOXY Screed MIXING PROCEDURE - Mix Component A (resin) for about 30 seconds.
- Add Component B (the hardener) over Component A.
- While mixing Components A + B, gradually add the quartz sand
- IMPORTANT: Do not over mix. Mix Components A + B continuously for 2 minutes until a uniform mixture is obtained.
- To make sure they are mixed evenly, pour the contents into another container and mix until a homogeneous mixture is obtained.
- In the final mixing phase, scrape the sides and bottom of the container with a straight/flat-edged spatula or trowel at least once to ensure thorough mixing.
APPLICATIONIMPORTANT Protect from moisture After application, the Product must be protected from moisture, condensation and direct contact with water for a period of at least 24 hours. IMPORTANT Damage to the finish due to heating with fossil fuel appliances Fossil fuel heat sources powered by gas, oil or paraffin produce large amounts of carbon dioxide and water vapor, which can adversely affect the surface finish. - For temporary heating, use only electrical equipment (air heaters, etc.). Do not use gas, oil, paraffin or other fossil fuel heat sources.
IMPORTANT Pinpoint defects If the Product is applied to porous substrates at elevated ambient temperatures, "needle-prick" defects may result. - Apply the Product at decreasing ambient temperatures.
IMPORTANT Pinpoint defect repair Applying the next layer to a primed substrate that has "pinprick" type defects can lead to similar defects in it. Repair the defects by following these steps: - Lightly sand the primed surface (completely dry).
- Apply a leveling and pore closing layer consisting of the mixed Product and an addition of ~3% Sika® Extender T.
STANDARD PRIMER APPLICATION - Pour the mixed Product onto the backing layer. Note: Consumption is specified in the "Application Information" section.
- Apply the Product evenly to the surface using a roller or rubber squeegee.
- Uniformize by rolling with the short hair stencil in two perpendicular directions, in a cross. Note: To achieve a seamless finish, keep the "wet edge" during application.
- If quartz sand spreading is required, wait 15 to 30 minutes, then spread quartz sand over the surface, first lightly dispersed, then to excess.
- IMPORTANT Make sure that the waiting/recoating times are respected before applying the following products (see "Waiting/recoating time" section). Once the product has cured sufficiently, remove all unincorporated sand using industrial vacuum equipment.
LEVELING MORTAR / LEVELING AND PORE CLOSING LAYER EQUIPMENT - Pour the mixed Product onto the backing layer. Note: Consumption is specified in the "Application Information" section.
- Apply the Product evenly to the surface with a rubber squeegee or trowel.
CONNECTING BRIDGE - Pour the mixed Product onto the backing layer. Note: Consumption is specified in the "Application Information" section.
- Apply the Product evenly to the surface using a roller, rubber squeegee or brush.
- Uniformize by rolling with the short hair stencil in two perpendicular directions, in a cross. Note: To achieve a seamless finish, keep the "wet edge" during application.
- ( Optional ) If necessary, apply second coat of primer.
EPOXY Screed IMPORTANT It is not suitable for direct contact with water - The product is not suitable for direct contact with water unless sealed with a suitable cover. Apply the mixed product "wet on wet" on the still sticky primer. Note: Consumption is specified in the "Application Information" section.
- Spread and compact the Product with a trowel to the required thickness between the guide rails, if installed.
- Level the surface of the screed with a leveling beam that rests on the guide rails.
- Finish the surface to the required appearance using a trowel or push concrete finishers (helicopters).
REPAIR MORTAR - Apply the mixed product "wet on wet" on the still sticky primer.
- Apply the Product with a trowel/trowel to the required thickness.
- Compact the applied product with a trowel. Smooth the surface with a trowel.
- IMPORTANT Make sure that the waiting/recoating times are respected before applying the following products (See the heading "Waiting/recoating time").
CLEANING OF TOOLSClean all tools and application equipment with Sika® Thinner C immediately after use. The already hardened material can only be removed mechanically. |