2-part epoxy high build textured coating and seal coat Sikafloor-264 N Thixo is a 2-part epoxy coloured thixotropic resin that can provide a hard wearing, seamless, low maintenance, textured gloss and slip resistant finish. Varying thickness’s can be achieved from 1.0–3.0 mm depending on the system used. For medium - heavy wear conditions. Internal use. - Seamless
- Good chemical and mechanical resistance
- Easy application
- Waterproof
- Gloss finish
- Easy cleanable slip resistant surface
- Slip resistant surface to suit clients requirements without use of aggregates.
- Low maintenance
|
Usage - High build textured coating for concrete and cementitious screeds with normal up to medium heavy wear e.g. storage and assembly halls, maintenance workshops, garages and loading ramps
- High build textured coating for areas, where slip resistance and easy cleanability is required
- Seal /Top coat for slip resistant textured systems, such as multi-storey and underground car park decks, maintenance hangars and for wet process areas, e.g. beverage and food industry
Advantages - Seamless
- Good chemical and mechanical resistance
- Easy application
- Waterproof
- Gloss finish
- Easy cleanable slip resistant surface
- Slip resistant surface to suit clients requirements without use of aggregates.
- Low maintenance
Packaging Part A | 23.7 kg containers | Part B | 6.3 kg containers | Part A+B | 30 kg ready to mix units | Colour Resin - part A: | coloured, liquid | Hardener - part B | transparent, liquid |
RAL 3003, 5010, 6010, 7011, 7032, 7035, 7038, 9005, 9010 Under direct sun light there may be some discolouration and colour variation. This has no influence on the function and performance of the coating. |
Technical Information Shore D Hardness ~76 (7 days / +23 °C) | (DIN 53 505) |
Compressive Strength ~60 N/mm2 (Resin filled 1:0.9 with F34) (28 days / +23 °C) | (EN196-1) |
Flexural Strength ~30 N/mm2 (Resin filled 1:0.9 with F34) (28 days / +23 °C) | (EN196-1) |
Tensile adhesion strength > 1.5 N/mm² (failure in concrete) | (ISO 4624) |
Chemical Resistance Resistant to many chemicals. Contact Sika Technical Service for specific information. Thermal Resistance Exposure* | Dry heat | Permanent | +50 °C | Short-term max. 7 d | +80 °C | Short-term max. 12 h | +100 °C |
Short-term moist/wet heat* up to +80 °C where exposure is only occasional (steam cleaning etc.). *No simultaneous chemical and mechanical exposure and only in combination with Sikafloor systems as a broadcast system with approx. 3 - 4 mm thickness. |
Application Information Mixing Ratio Part A : part B = 79 : 21 (by weight) Ambient Air Temperature +10 °C min. / +30 °C max. Relative Air Humidity 80 % r.h. max. Dew Point Beware of condensation! The substrate and uncured floor must be at least 3 °C above dew point to reduce the risk of condensation or blooming on the floor finish. Note: Low temperatures and high humidity conditions increase the probability of blooming. Substrate Temperature +10 °C min. / +30 °C max. Substrate Moisture Content ≤ 4% pbw Test method: Sika-Tramex meter, CM-measurement or oven-dry-method. No rising moisture according to ASTM (Polyethylene-sheet). Pot Life Temperature | Time | +10 °C | ~50 minutes | +20 °C | ~25 minutes | +30 °C | ~15 minutes | Curing Time Before applying Sikafloor-264 N Thixo on Sikafloor-156/-161 /-160 allow: Substrate temperature | Minimum | Maximum | +10 °C | 24 hours | 3 days | +20 °C | 12 hours | 2 days | +30 °C | 8 hours | 24 hours |
Before applying Sikafloor-264 N Thixo on Sikafloor-263 SL N/-264 N allow: Substrate temperature | Minimum | Maximum | +10 °C | 30 hours | 3 days | +20 °C | 24 hours | 2 days | +30 °C | 16 hours | 1 day |
Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity. Applied Product Ready for Use Temperature | Foot traffic | Light traffic | Full cure | +10 °C | ~72 hours | ~6 days | ~10 days | +20 °C | ~24 hours | ~4 days | ~7 days | +30 °C | ~18 hours | ~2 days | ~5 days |
Note: Times are approximate and will be affected by changing ambient conditions. |
The above design is only a sample of the options available, for reference purposes only. Our policy of continuous improvement may result in a change of specifications without notice. If any discrepencies might be between the data sheet values and standards, we reserve the rights to make technical changes. Our company will not be held responsible, as all or any of pictures, drawings, weights and dimensions details or other elements in this document are only indicative and must not be considered contractual. Contact our sales team for other specifications or custom made products.
Contact our sales team for other specifications or custom made products.