Sikafloor-260 PurCem, 25Kg
SIKA
Sika is a global leader in specialty chemicals for the construction and industrial sectors. The company develops and supplies innovative products and systems for bonding, sealing, damping, reinforcing, and protecting structures. With a strong focus on sustainability and performance, Sika serves a wide range of applications including concrete production, waterproofing, roofing, flooring, and structural strengthening.
Read moreSelf-leveling hybrid polyurethane-cement screed, glossy, resistant to thermal shock, with high chemical and mechanical resistance Sikafloor®-260 PurCem® is a self-levelling hybrid, polyurethane-cement, water-based, multi-component, colored screed. It ensures a smooth, glossy surface with good chemical resistance, intense abrasion and impact. | ||||||||||||||||||||||||||||||||||||||||
UseThe product is used as a wear layer, base layer or leveling and pore closing layer within Sikafloor® PurCem® floor systems. Note:
Advantages
pack
See the current price list for available packaging. Color
Notes: When the applied Product is exposed to direct sunlight, some discoloration and color variations may occur. This has no influence on the functionality and performance of the Product. To evaluate and confirm the selected color, perform test applications in real lighting conditions. | ||||||||||||||||||||||||||||||||||||||||
Typical technical data
| ||||||||||||||||||||||||||||||||||||||||
ApplicationMixture ratio
Layer thickness
Product temperature
Ambient air temperature
The relative humidity of the air
Dew point Beware of condensation. To reduce the risk of condensation or efflorescence on the finished surface, the temperature of the substrate and the freshly applied material must be at least +3 °C (+37 °F) higher than the dew point temperature. Low temperatures and high relative humidity increase the probability of surface efflorescence. Support temperature
Moisture content in the substrate The product can be applied on dry substrates or with moisture content higher than 4% (CM Method). The support must not have standing water on the surface and have a pull-out strength of at least 1.5 N/mm 2 (218 psi) (EN 1542). The support must not have rising moisture (ASTM D4263, polyethylene film test). Lifetime of the mixture
Waiting Time / Recoating Before re-covering the Product, a waiting time will be ensured as follows:
Note: Times are approximate and are affected by changes in ambient conditions, especially temperature and relative humidity. Note: If instead of the Sikafloor® PurCem®-based leveling and pore-closing layer you use another Sika® priming product, please observe the recoating times indicated in the Technical Data Sheet of the respective Product. Ensure that the primer or leveling and pore-closing layer is fully cured before applying the Sikafloor® PurCem® wear layer. Consumption ~1.8 kg/m² per mm thickness EQUIPMENT MIXING EQUIPMENT
APPLICATION EQUIPMENT
SUPPORT QUALITY TREATMENT OF JOINTS AND CRACKS IMPORTANT Incorrect treatment of cracks Incorrect assessment and treatment of cracks can lead to a reduced life of the finish and re-occurrence of cracks. Existing construction joints and static surface cracks require treatment before the system is applied. Use resin-based products from the Sikafloor® and Sikadur® ranges to level and fill them. The system can be applied to freshly poured or wet concrete without standing water. Wait at least 3 days after pouring the concrete to allow the initial shrinkage to wear out, thus preventing shrinkage cracking on the wearing surface. The cement base layer (concrete/screed) must be solid and have sufficient compressive strength (minimum 25 N/mm 2 (3626 psi) ) with a pull-out strength of at least 1.5 N/mm 2 (218 psi) . The substrate must be clean and free of contamination, such as: impurities, residues, oil, grease, coatings or previous surface treatments, friable materials, etc. shuffle IMPORTANT Only mix complete sets PROCEDURE FOR MIXING 3 COMPONENTS
PROCEDURE FOR MIXING 4 COMPONENTS
APPLICATION IMPORTANT Protection of the material after application After application, protect the System from moisture, condensation and direct contact with water for at least 24 hours. IMPORTANT Protection of the material from condensation and accidental leaks During application, protect the Product from condensation or any leaks from ceiling fixtures. IMPORTANT Ventilation of closed spaces Always ensure good ventilation when applying the Product in enclosed spaces. IMPORTANT Applications on screeds based on modified polymer cement Do not apply to polymer modified cementitious screed substrates. When sealed with an impermeable resin, in the presence of moisture they can expand. LEVELING AND PORE CLOSING LAYER
WEAR LAYER
CLEANING OF TOOLS Clean all tools and application equipment with Sika® Thinner C immediately after use. The already hardened material can only be removed mechanically. |