Elastic, 1-component adhesive for the SikaMembran system SikaBond TF plus N is a 1-component, PU-based adhesive for the SikaMembran facade membrane system, which combines high mechanical strength with the necessary elasticity to cope with high movements in facades. SikaBond TF plus N adheres excellent to a wide range of substrates. - Secure application with good sag resistance
- Bonds well to concrete, aluminium (anodized or powder-coated), rigid U-PVC, timber and other standard construction materials
- Application of adhesive to one side only (mostly to substrate)
- Ensures levelling of substrate
- No contact pressure necessary
- Fast curing
- Adjustment of membrane possible until 30 min. after installation
|
PRODUCT BENEFITS - Secure application with good sag resistance
- Bonds well to concrete, aluminium (anodized or powder-coated), rigid U-PVC, timber and other standard construction materials
- Application of adhesive to one side only (mostly to substrate)
- Ensures levelling of substrate
- No contact pressure necessary
- Fast curing
- Adjustment of membrane possible until 30 min. after installation
Usage SikaBond TF plus N is used for bonding SikaMembran facade membranes (e.g. SikaMembran Universal, Outdoor, Outdoor plus, Strong, Eco Uni, Eco Out) behind curtain walling and rainscreen cladding. SikaBond TF plus N is also suitable to bond over-plasterable membranes (e.g. SikaMembran Uni-P) to concrete and brick wall in window installation. This product is suitable for experienced professional users only. Tests with actual substrates and conditions have to be performed to ensure adhesion and material compatibility. |
Typical Product DataChemical base | | 1-component polyurethane | Colour (CQP001-1) | | Black | Cure mechanism | | Moisture-curing | Density (uncured) | | 1.3 kg/l | Non-sag properties | | Good | Application temperature | ambient, substrate | 5 ─ 40 °C | Skin time (CQP019-1) | | 190 minutes A | Shore A hardness (CQP023-1 / ISO 48-4) | | 30 B | Tensile strength (CQP036-1 / ISO 527) | | 1.5 MPa | Elongation at break (CQP036-1 / ISO 527) | | 650 % | Tensile lap-shear strength (CQP046-1 / ISO 4587) | | 0.6 MPa C | Service temperature (CQP509-1 / CQP513-1) | | -40 ─ 90 °C | Shelf life | | 12 months D |
CQP = Corporate Quality Procedure | A)23 °C / 50 % r. h. B)14 days at 23 °C / 50 % r. h. | C)7 days at 23 °C / 50 % r. h. | D)storage below 25 °C |
|
Technical Information CURE MECHANISM SikaBond TF plus N cures by reaction with atmospheric moisture. At low temperatures the water content of the air is generally lower and the curing reaction proceeds some-what slower. |
Application Information Surface Preparation Surfaces must be clean, dry and free from grease, oil, dust and contaminants. Surface treatment depends on the specific nature of the substrates and is crucial for a long lasting bond. Treat non-porous surfaces with Sika Aktivator-205. Clean porous surfaces by wire brush and/or vacuum. On porous substrates exposed frequently to water use Sika Primer-210 or Sika Primer-3 N. Consider that these suggestions are based on experience and have in any case to be verified by tests on original substrates. Application SikaBond TF plus N can be processed between 5 °C and 40 °C but changes in reactivity and application properties have to be considered. The optimum temperature for substrate and adhesive is between 15 °C and 25 °C. Until the adhesive is fully cured the substrate temperature must be in between 5 °C and 40 °C. To avoid condensation on the surfaces, the temperature of the bonding substrates must be at least 3 °C higher than the dew point of the air. The skin time is significantly shorter in hot and humid climate. The SikaMembran must always be installed within half of the skin time. Never join bonding parts if the adhesive has built a skin. SikaBond TF plus N can be processed with hand, pneumatic or electric driven piston guns. Removal Uncured SikaBond TF plus N can be removed from tools and equipment with Sika Remover-208 or another suitable solvent. Once cured, the material can only be removed mechanically. Hands and exposed skin have to be washed immediately using hand wipes such as Sika Cleaner-350H or a suitable industrial hand cleaner and water. Do not use solvents on skin. Application Limits Where two or more different reactive sealants are used, allow the first to cure completely before applying the next. The compatibility of gaskets, backer rods, and other accessory materials in contact with SikaBond TF plus N must be tested in advance. Don’t use the adhesive directly on bituminous, plasticiser bleeding or formwork oil containing substrates. |
The above design is only a sample of the options available, for reference purposes only. Our policy of continuous improvement may result in a change of specifications without notice. If any discrepencies might be between the data sheet values and standards, we reserve the rights to make technical changes. Our company will not be held responsible, as all or any of pictures, drawings, weights and dimensions details or other elements in this document are only indicative and must not be considered contractual. Contact our sales team for other specifications or custom made products.
Contact our sales team for other specifications or custom made products.